How to use the niswitch.visatype.ViInt32 function in niswitch

To help you get started, we’ve selected a few niswitch examples, based on popular ways it is used in public projects.

Secure your code as it's written. Use Snyk Code to scan source code in minutes - no build needed - and fix issues immediately.

github ni / nimi-python / generated / niswitch / unit_tests / matchers.py View on Github external
def __init__(self, expected_size_or_value):
        _BufferMatcher.__init__(self, visatype.ViInt32, expected_size_or_value)
github ni / nimi-python / generated / niswitch / session.py View on Github external
index. Use get_channel_name in a For Loop to get a complete list
        of valid channel names for the switch module. Use the Channel Count
        attribute to determine the number of channels.

        Args:
            index (int): A 1-based index into the channel table. Default value: 1 Maximum value:
                Value of Channel Count attribute.

        '''
        vi_ctype = visatype.ViSession(self._vi)  # case S110
        index_ctype = visatype.ViInt32(index)  # case S150
        buffer_size_ctype = visatype.ViInt32()  # case S170
        channel_name_buffer_ctype = None  # case C050
        error_code = self._library.niSwitch_GetChannelName(vi_ctype, index_ctype, buffer_size_ctype, channel_name_buffer_ctype)
        errors.handle_error(self, error_code, ignore_warnings=True, is_error_handling=False)
        buffer_size_ctype = visatype.ViInt32(error_code)  # case S180
        channel_name_buffer_ctype = (visatype.ViChar * buffer_size_ctype.value)()  # case C060
        error_code = self._library.niSwitch_GetChannelName(vi_ctype, index_ctype, buffer_size_ctype, channel_name_buffer_ctype)
        errors.handle_error(self, error_code, ignore_warnings=False, is_error_handling=False)
        return channel_name_buffer_ctype.value.decode(self._encoding)
github ni / nimi-python / generated / niswitch / session.py View on Github external
current execution thread. If the InstrumentHandle parameter is an
        invalid session, the function does nothing and returns an error.
        Normally, the error information describes the first error that occurred
        since the user last called _get_error or ClearError.

        Note:
        One or more of the referenced functions are not in the Python API for this driver.

        Returns:
            code (int): Returns the error code for the session or execution thread. If you pass
                0 for the Buffer Size, you can pass VI_NULL for this parameter.

        '''
        vi_ctype = visatype.ViSession(self._vi)  # case S110
        code_ctype = visatype.ViStatus()  # case S200
        buffer_size_ctype = visatype.ViInt32()  # case S170
        description_ctype = None  # case C050
        error_code = self._library.niSwitch_GetError(vi_ctype, None if code_ctype is None else (ctypes.pointer(code_ctype)), buffer_size_ctype, description_ctype)
        errors.handle_error(self, error_code, ignore_warnings=True, is_error_handling=True)
        buffer_size_ctype = visatype.ViInt32(error_code)  # case S180
        description_ctype = (visatype.ViChar * buffer_size_ctype.value)()  # case C060
        error_code = self._library.niSwitch_GetError(vi_ctype, None if code_ctype is None else (ctypes.pointer(code_ctype)), buffer_size_ctype, description_ctype)
        errors.handle_error(self, error_code, ignore_warnings=False, is_error_handling=True)
        return int(code_ctype.value), description_ctype.value.decode(self._encoding)
github ni / nimi-python / generated / niswitch / session.py View on Github external
names: ch0, com0, ab0, r1, c2, cjtemp Default value: ""

            channel2 (str): Input one of the channel names of the desired path. Pass the other
                channel name as the channel 1 parameter. Refer to Devices Overview for
                valid channel names for the switch module. Examples of valid channel
                names: ch0, com0, ab0, r1, c2, cjtemp Default value: ""

        '''
        vi_ctype = visatype.ViSession(self._vi)  # case S110
        channel1_ctype = ctypes.create_string_buffer(channel1.encode(self._encoding))  # case C020
        channel2_ctype = ctypes.create_string_buffer(channel2.encode(self._encoding))  # case C020
        buffer_size_ctype = visatype.ViInt32()  # case S170
        path_ctype = None  # case C050
        error_code = self._library.niSwitch_GetPath(vi_ctype, channel1_ctype, channel2_ctype, buffer_size_ctype, path_ctype)
        errors.handle_error(self, error_code, ignore_warnings=True, is_error_handling=False)
        buffer_size_ctype = visatype.ViInt32(error_code)  # case S180
        path_ctype = (visatype.ViChar * buffer_size_ctype.value)()  # case C060
        error_code = self._library.niSwitch_GetPath(vi_ctype, channel1_ctype, channel2_ctype, buffer_size_ctype, path_ctype)
        errors.handle_error(self, error_code, ignore_warnings=False, is_error_handling=False)
        return path_ctype.value.decode(self._encoding)
github ni / nimi-python / generated / niswitch / session.py View on Github external
Note:
        One or more of the referenced functions are not in the Python API for this driver.

        Returns:
            code (int): Returns the error code for the session or execution thread. If you pass
                0 for the Buffer Size, you can pass VI_NULL for this parameter.

        '''
        vi_ctype = visatype.ViSession(self._vi)  # case S110
        code_ctype = visatype.ViStatus()  # case S200
        buffer_size_ctype = visatype.ViInt32()  # case S170
        description_ctype = None  # case C050
        error_code = self._library.niSwitch_GetError(vi_ctype, None if code_ctype is None else (ctypes.pointer(code_ctype)), buffer_size_ctype, description_ctype)
        errors.handle_error(self, error_code, ignore_warnings=True, is_error_handling=True)
        buffer_size_ctype = visatype.ViInt32(error_code)  # case S180
        description_ctype = (visatype.ViChar * buffer_size_ctype.value)()  # case C060
        error_code = self._library.niSwitch_GetError(vi_ctype, None if code_ctype is None else (ctypes.pointer(code_ctype)), buffer_size_ctype, description_ctype)
        errors.handle_error(self, error_code, ignore_warnings=False, is_error_handling=True)
        return int(code_ctype.value), description_ctype.value.decode(self._encoding)
github ni / nimi-python / generated / niswitch / session.py View on Github external
accurate count. Refer to the Relay Count topic in the NI Switches Help
        to determine if the switch module supports relay counting.

        Args:
            relay_name (str): Name of the relay. Default value: None Examples of valid relay names:
                ch0, ab0, 1wire, hlselect Refer to Devices Overview for a list of valid
                relay names for the switch module.


        Returns:
            relay_count (int): The number of relay cycles.

        '''
        vi_ctype = visatype.ViSession(self._vi)  # case S110
        relay_name_ctype = ctypes.create_string_buffer(relay_name.encode(self._encoding))  # case C020
        relay_count_ctype = visatype.ViInt32()  # case S200
        error_code = self._library.niSwitch_GetRelayCount(vi_ctype, relay_name_ctype, None if relay_count_ctype is None else (ctypes.pointer(relay_count_ctype)))
        errors.handle_error(self, error_code, ignore_warnings=False, is_error_handling=False)
        return int(relay_count_ctype.value)
github ni / nimi-python / generated / niswitch / session.py View on Github external
def get_relay_name(self, index):
        '''get_relay_name

        Returns the relay name string that is in the relay list at the specified
        index. Use get_relay_name in a For Loop to get a complete list
        of valid relay names for the switch module. Use the Number of Relays
        attribute to determine the number of relays.

        Args:
            index (int): A 1-based index into the channel table. Default value: 1 Maximum value:
                Value of Channel Count attribute.

        '''
        vi_ctype = visatype.ViSession(self._vi)  # case S110
        index_ctype = visatype.ViInt32(index)  # case S150
        relay_name_buffer_size_ctype = visatype.ViInt32()  # case S170
        relay_name_buffer_ctype = None  # case C050
        error_code = self._library.niSwitch_GetRelayName(vi_ctype, index_ctype, relay_name_buffer_size_ctype, relay_name_buffer_ctype)
        errors.handle_error(self, error_code, ignore_warnings=True, is_error_handling=False)
        relay_name_buffer_size_ctype = visatype.ViInt32(error_code)  # case S180
        relay_name_buffer_ctype = (visatype.ViChar * relay_name_buffer_size_ctype.value)()  # case C060
        error_code = self._library.niSwitch_GetRelayName(vi_ctype, index_ctype, relay_name_buffer_size_ctype, relay_name_buffer_ctype)
        errors.handle_error(self, error_code, ignore_warnings=False, is_error_handling=False)
        return relay_name_buffer_ctype.value.decode(self._encoding)
github ni / nimi-python / generated / niswitch / session.py View on Github external
scan_delay (float): The minimum length of time you want the switch device to wait after it
                creates a path until it asserts a trigger on the scan advanced output
                line. The driver uses this value to set the Scan Delay attribute. The
                scan delay is in addition to the settling time.The driver uses this
                value to set the scan_delay attribute. Express this
                value in seconds. Default value: 0.0 s

        '''
        if type(trigger_input) is not enums.TriggerInput:
            raise TypeError('Parameter mode must be of type ' + str(enums.TriggerInput))
        if type(scan_advanced_output) is not enums.ScanAdvancedOutput:
            raise TypeError('Parameter mode must be of type ' + str(enums.ScanAdvancedOutput))
        vi_ctype = visatype.ViSession(self._vi)  # case S110
        scan_delay_ctype = visatype.ViReal64(scan_delay)  # case S150
        trigger_input_ctype = visatype.ViInt32(trigger_input.value)  # case S130
        scan_advanced_output_ctype = visatype.ViInt32(scan_advanced_output.value)  # case S130
        error_code = self._library.niSwitch_ConfigureScanTrigger(vi_ctype, scan_delay_ctype, trigger_input_ctype, scan_advanced_output_ctype)
        errors.handle_error(self, error_code, ignore_warnings=False, is_error_handling=False)
        return
github ni / nimi-python / generated / niswitch / session.py View on Github external
TriggerInput.TTL2 TriggerInput.TTL3 TriggerInput.TTL4
                TriggerInput.TTL5 TriggerInput.TTL6 TriggerInput.TTL7

                Note:
                One or more of the referenced values are not in the Python API for this driver. Enums that only define values, or represent True/False, have been removed.

            invert (bool): If VI_TRUE, inverts the input trigger signal from falling to rising or
                vice versa. Default value: VI_FALSE

        '''
        if type(trigger_input_connector) is not enums.TriggerInput:
            raise TypeError('Parameter mode must be of type ' + str(enums.TriggerInput))
        if type(trigger_input_bus_line) is not enums.TriggerInput:
            raise TypeError('Parameter mode must be of type ' + str(enums.TriggerInput))
        vi_ctype = visatype.ViSession(self._vi)  # case S110
        trigger_input_connector_ctype = visatype.ViInt32(trigger_input_connector.value)  # case S130
        trigger_input_bus_line_ctype = visatype.ViInt32(trigger_input_bus_line.value)  # case S130
        invert_ctype = visatype.ViBoolean(invert)  # case S150
        error_code = self._library.niSwitch_RouteTriggerInput(vi_ctype, trigger_input_connector_ctype, trigger_input_bus_line_ctype, invert_ctype)
        errors.handle_error(self, error_code, ignore_warnings=False, is_error_handling=False)
        return